Product no. RS301ON-III
RS301ON-III Hydrogen Quality Analyzer
Integrated online hydrogen quality analysis for purity, humidity, oxygen content, and residual hydrogen monitoring in generator hydrogen systems.
Key Product Data
- Purity range
- H2/Air 90 to 100%; CO2/H2 0 to 100%; CO2/Air 0 to 100%
- Humidity range
- -80 to 20 C
- Oxygen range
- 0 to 25 %
- Residual hydrogen range
- 0 to 4 %Vol
- Purity error
- Plus or minus 2% F.S
- Humidity error
- Plus or minus 2 C
- Oxygen error
- Plus or minus 1% F.S
- Model
- RS301ON-III
Product Overview
Integrated online hydrogen quality analysis for purity, humidity, oxygen content, and residual hydrogen monitoring in generator hydrogen systems.
Product Advantages
- Integrated analysis of purity, humidity, oxygen, and residual hydrogen
- Built for generator hydrogen system quality monitoring
- Combines multiple explosion-proof analyzer modules
Technical Specifications
15 parameters- Purity range
- H2/Air 90 to 100%; CO2/H2 0 to 100%; CO2/Air 0 to 100%
- Humidity range
- -80 to 20 C
- Oxygen range
- 0 to 25 %
- Residual hydrogen range
- 0 to 4 %Vol
- Purity error
- Plus or minus 2% F.S
- Humidity error
- Plus or minus 2 C
- Oxygen error
- Plus or minus 1% F.S
- Model
- RS301ON-III
- Type
- Integrated online hydrogen quality analyzer
- Purity principle
- Micro thermal conductivity
- Humidity principle
- Resistive-capacitive
- Oxygen principle
- Electrochemical
- Residual hydrogen principle
- Catalytic combustion
- Residual hydrogen error
- Plus or minus 1% F.S
- Explosion-proof
- Ex d IIB + H2 T5 Gb / Ex d IIC T6 Gb
Application and Selection Checklist
This product is listed for integrated hydrogen quality analysis. Before selection, provide the following project information so the configuration can be reviewed against the actual operating conditions.
- Gas composition and operating conditions
- Required range, capacity, flow, or response
- Power supply, interfaces, and installation space
- Site environment and destination country
- Quantity, schedule, and operating workflow
- Required standards, drawings, tests, and certificates
Standards, Documentation, and Project Fit
Product suitability is determined by the selected model, configuration, operating conditions, interfaces, and destination requirements. A matching product in the same group is not automatically interchangeable.
Standards, declarations, calibration records, inspection documents, drawings, manuals, commissioning, training, and test scope vary by product and contract. State every required item in the inquiry and confirm it in writing before purchase.
Typical application descriptions on this page are selection references, not claims about a named customer installation. Final project fit requires review of the actual site data.
Frequently Asked Questions
What is RS301ON-III Hydrogen Quality Analyzer used for?
RS301ON-III Hydrogen Quality Analyzer is intended for integrated hydrogen quality analysis. Integrated online hydrogen quality analysis for purity, humidity, oxygen content, and residual hydrogen monitoring in generator hydrogen systems.
Which product group does RS301ON-III belong to?
RS301ON-III is listed in the H2 Gas analyzers product group within the Hydrogen range.
What should be confirmed before selecting RS301ON-III?
Confirm the application, gas conditions, required performance, utilities, connection interfaces, site environment, quantity, destination, and required technical documents.
Are standards and certificates available for RS301ON-III?
Applicable standards, declarations, calibration or inspection records, and certificate availability depend on the selected model and destination. Confirm required documents in writing during the inquiry.
Related Selection Guides and Products
Product Images
1 image