Product no. RS-301ON
RS-301ON Hydrogen Purity Analyzer
Fixed hydrogen purity analysis for hydrogen-cooled generator units with sampling, temperature compensation, and long-term stable monitoring.
Key Product Data
- Measurement range
- CO2 in air 0 to 100%; CO2 in H2 0 to 100%; H2 in air 90 to 100%
- Accuracy
- Plus or minus 2% F.S
- Output
- 4 to 20 mA, factory setting H2 in air 90 to 100%
- Explosion-proof rating
- Ex d IIC T6 Gb
- Sample gas flow
- 0.5 SCFH
- Power
- AC 90 to 265 V, 50 Hz, 35 W
- Model
- RS-301ON
- Type
- Fixed hydrogen purity analyzer
Product Overview
Fixed hydrogen purity analysis for hydrogen-cooled generator units with sampling, temperature compensation, and long-term stable monitoring.
Product Advantages
- Fixed analyzer for hydrogen-cooled generator purity monitoring
- Covers CO2 and H2 gas replacement measurement ranges
- Explosion-proof design for industrial hydrogen environments
Technical Specifications
13 parameters- Measurement range
- CO2 in air 0 to 100%; CO2 in H2 0 to 100%; H2 in air 90 to 100%
- Accuracy
- Plus or minus 2% F.S
- Output
- 4 to 20 mA, factory setting H2 in air 90 to 100%
- Explosion-proof rating
- Ex d IIC T6 Gb
- Sample gas flow
- 0.5 SCFH
- Power
- AC 90 to 265 V, 50 Hz, 35 W
- Model
- RS-301ON
- Type
- Fixed hydrogen purity analyzer
- Dimensions
- 800 mm x 400 mm x 1660 mm
- Weight
- 130 kg
- Maximum load
- 800 ohm
- Alarm relay
- Contact current 3 A
- Sampling pressure
- Less than or equal to 0.1 MPa
Application and Selection Checklist
This product is listed for fixed hydrogen purity analysis. Before selection, provide the following project information so the configuration can be reviewed against the actual operating conditions.
- Gas composition and operating conditions
- Required range, capacity, flow, or response
- Power supply, interfaces, and installation space
- Site environment and destination country
- Quantity, schedule, and operating workflow
- Required standards, drawings, tests, and certificates
Standards, Documentation, and Project Fit
Product suitability is determined by the selected model, configuration, operating conditions, interfaces, and destination requirements. A matching product in the same group is not automatically interchangeable.
Standards, declarations, calibration records, inspection documents, drawings, manuals, commissioning, training, and test scope vary by product and contract. State every required item in the inquiry and confirm it in writing before purchase.
Typical application descriptions on this page are selection references, not claims about a named customer installation. Final project fit requires review of the actual site data.
Frequently Asked Questions
What is RS-301ON Hydrogen Purity Analyzer used for?
RS-301ON Hydrogen Purity Analyzer is intended for fixed hydrogen purity analysis. Fixed hydrogen purity analysis for hydrogen-cooled generator units with sampling, temperature compensation, and long-term stable monitoring.
Which product group does RS-301ON belong to?
RS-301ON is listed in the H2 Gas analyzers product group within the Hydrogen range.
What should be confirmed before selecting RS-301ON?
Confirm the application, gas conditions, required performance, utilities, connection interfaces, site environment, quantity, destination, and required technical documents.
Are standards and certificates available for RS-301ON?
Applicable standards, declarations, calibration or inspection records, and certificate availability depend on the selected model and destination. Confirm required documents in writing during the inquiry.
Related Selection Guides and Products
Product Images
1 image