RF151 MID SF6 Gas Handling
SF6
MID handlingPLC controlSF6 recovery

Product no. RF-151

RF151 MID SF6 Gas Handling

Medium SF6 gas handling unit for vacuum evacuation, gas recovery, refilling, cylinder pressurizing, and vaporized gas output.

Gas type
SF6
Product group
SF6 Service carts
Application
Medium-capacity gas handling

Key Product Data

Gas
SF6
Application range
10 to 40.5 kV gas-insulated switchgear; 72.5 to 330 kV circuit breakers and GIS; 500 kV circuit breakers
Model options
10 standard configurations
Control modes
One-button control (K) or touch screen control (T)
Vacuum pump options
17 m3/h (B1) or 64 m3/h (B2), final vacuum <= 10 Pa
Storage tank options
No tank / 120 L / 300 L / 600 L / 1000 L external tank
Vacuum compressor options
15 m3/h <= 5000 Pa; 20 m3/h <= 50 Pa
Recovery rate
0 to 60 kg/h
10 standard configurations cover one-button or touch screen control, vacuum compressor options, vacuum pump options, and storage tank options
PLC control and touch screen operation show vacuum changes during evacuation and make operation simple
Four refilling modes are available: direct filling, regulated pressure output, gas-phase pressurizing, and liquid-phase pressurizing
Back to catalogue

Product Overview

The RF-151 Series is a medium SF6 gas handling unit. It is a PLC-controlled semi-intelligent system for SF6 gas recovery, evacuation, refilling, cylinder pressurizing, and vaporized gas output.

The unit is designed for comprehensive gas service on SF6 electrical equipment and switchgear. It is suitable for power utilities, metallurgy, petrochemical plants, high-voltage switchgear factories, research institutes, and training applications.

RF-151 covers 10 to 40.5 kV gas-insulated switchgear, 72.5 to 330 kV circuit breakers and GIS, and 500 kV circuit-breaker service.

Product Advantages

  • 10 standard configurations cover one-button or touch screen control, vacuum compressor options, vacuum pump options, and storage tank options
  • PLC control and touch screen operation show vacuum changes during evacuation and make operation simple
  • Four refilling modes are available: direct filling, regulated pressure output, gas-phase pressurizing, and liquid-phase pressurizing
  • Oil-free recovery compressor and refrigeration liquefaction system improve recovery speed and reduce residual gas
  • Molecular sieve filtering and drying removes moisture, decomposition products, and other impurities
  • Covers 10 to 40.5 kV gas-insulated switchgear, 72.5 to 330 kV circuit breakers and GIS, and 500 kV circuit breakers
  • Compact semi-closed protective structure makes operation and maintenance convenient
  • Real-time inlet and outlet pressure indication supports safer operation

Technical Specifications

32 parameters
Gas
SF6
Application range
10 to 40.5 kV gas-insulated switchgear; 72.5 to 330 kV circuit breakers and GIS; 500 kV circuit breakers
Model options
10 standard configurations
Control modes
One-button control (K) or touch screen control (T)
Vacuum pump options
17 m3/h (B1) or 64 m3/h (B2), final vacuum <= 10 Pa
Storage tank options
No tank / 120 L / 300 L / 600 L / 1000 L external tank
Vacuum compressor options
15 m3/h <= 5000 Pa; 20 m3/h <= 50 Pa
Recovery rate
0 to 60 kg/h
Oil-free compressor
15 m3/h standard published configuration
Evacuation speed
17 m3/h (B1) / 64 m3/h (B2)
Final vacuum
<= 10 Pa
Air content after treatment
<= 0.04% mass fraction
Moisture after treatment
<= 0.0005% mass fraction; dew point <= -49.5 °C
CF4 after treatment
<= 0.04% mass fraction
Outlet pressure
<= 3 MPa
Power supply
380 to 440 V / 50 Hz; 208 to 240 V / 60 Hz or 380 to 480 V / 60 Hz optional, three-phase
Model
RF-151
Type
MID SF6 gas handling unit
Function
Vacuum evacuation / recovery / refilling / cylinder pressurizing / vaporized output
Dimensions
2030 x 1230 x 1930 mm with tank; height 1260 mm without tank on legacy configuration
Weight
Approx. 1000 kg current published configuration
Standard
Designed and manufactured according to DL/T662
Liquid filling
Built-in filling machine; approximately 5 minutes for a 70 L cylinder
Tank working pressure
Max. 4.5 MPa on published carbon-steel tank configuration
Recovered SF6 purity
>= 99.9%
Acidity as HF
<= 0.00002% mass fraction
Decomposable fluoride as HF
<= 0.00010% mass fraction
Mineral oil
<= 0.0004% mass fraction
Recovery hose
DN19 x 10 m, DN20 self-sealing coupling on one end, ball valve and cylinder connector on the other end
Refilling hose
DN13 x 3 m, DN20 self-sealing coupling on one end, ball valve and cylinder connector on the other end
Power cable
10 m
Auxiliary recovery cooling
Water cooling

Selection Guide

RF-151 can be configured by control mode, vacuum compressor, vacuum pump, and storage tank volume. The listed models are the basic one-button configurations with A1 vacuum compressor. Touch screen control and A2 vacuum compressor options can be customized.

Model selection rule

CodeMeaningAvailable options
K / TControl modeK = one-button control; T = touch screen control
A1 / A2Vacuum compressorA1 = 15 m3/h <= 5000 Pa; A2 = 20 m3/h <= 50 Pa
B1 / B2Vacuum pumpB1 = 17 m3/h <= 10 Pa; B2 = 64 m3/h <= 10 Pa
C1-C5Storage tankC1 no tank, C2 120 L, C3 300 L, C4 600 L, C5 1000 L external tank

Available RF-151 models

ModelControl modeVacuum compressorVacuum pumpStorage tank
RF-151KA1B1C1One-button15 m3/h17 m3/hNo tank
RF-151KA1B1C2One-button15 m3/h17 m3/h120 L
RF-151KA1B1C3One-button15 m3/h17 m3/h300 L
RF-151KA1B1C4One-button15 m3/h17 m3/h600 L
RF-151KA1B1C5One-button15 m3/h17 m3/h1000 L external
RF-151KA1B2C1One-button15 m3/h64 m3/hNo tank
RF-151KA1B2C2One-button15 m3/h64 m3/h120 L
RF-151KA1B2C3One-button15 m3/h64 m3/h300 L
RF-151KA1B2C4One-button15 m3/h64 m3/h600 L
RF-151KA1B2C5One-button15 m3/h64 m3/h1000 L external

Standard accessories

AccessorySpecificationUse
Recovery hoseDN19 x 10 m, DN20 self-sealing coupling on one end, ball valve and cylinder connector on the other endGas recovery
Refilling hoseDN13 x 3 m, DN20 self-sealing coupling on one end, ball valve and cylinder connector on the other endGas refilling
Power cable10 mPower connection
Auxiliary recovery coolingWater coolingImproves recovery efficiency

Application and Selection Checklist

This product is listed for medium-capacity gas handling. Before selection, provide the following project information so the configuration can be reviewed against the actual operating conditions.

  • Gas composition and operating conditions
  • Required range, capacity, flow, or response
  • Power supply, interfaces, and installation space
  • Site environment and destination country
  • Quantity, schedule, and operating workflow
  • Required standards, drawings, tests, and certificates

Standards, Documentation, and Project Fit

Product suitability is determined by the selected model, configuration, operating conditions, interfaces, and destination requirements. A matching product in the same group is not automatically interchangeable.

Standards, declarations, calibration records, inspection documents, drawings, manuals, commissioning, training, and test scope vary by product and contract. State every required item in the inquiry and confirm it in writing before purchase.

Typical application descriptions on this page are selection references, not claims about a named customer installation. Final project fit requires review of the actual site data.

Frequently Asked Questions

What is RF151 MID SF6 Gas Handling used for?

RF151 MID SF6 Gas Handling is intended for medium-capacity gas handling. Medium SF6 gas handling unit for vacuum evacuation, gas recovery, refilling, cylinder pressurizing, and vaporized gas output.

Which product group does RF-151 belong to?

RF-151 is listed in the SF6 Service carts product group within the SF6 range.

What should be confirmed before selecting RF-151?

Confirm the application, gas conditions, required performance, utilities, connection interfaces, site environment, quantity, destination, and required technical documents.

Are standards and certificates available for RF-151?

Applicable standards, declarations, calibration or inspection records, and certificate availability depend on the selected model and destination. Confirm required documents in writing during the inquiry.

Related Selection Guides and Products

Product Images

1 image
RF151 MID SF6 Gas Handling product image 1