NA1000MS Fixed Hydrogen Leak Monitoring System
H2
Fixed1-16 channelsAlarm records

Product no. NA1000MS

NA1000MS Fixed Hydrogen Leak Monitoring System

Fixed hydrogen leak monitoring for continuous online safety coverage, multi-point monitoring, and alarm control support.

Gas type
Hydrogen
Product group
H2 Leakage monitoring
Application
Fixed multi-point safety monitoring

Key Product Data

Output
1 to 8 channels of 4 to 20 mA current output, up to 16 channels
Explosion-proof rating
Ex ia IIC T4 Ga
Model
NA1000MS
Type
Fixed multi-channel hydrogen leak monitoring and alarm system
Sampling method
Natural diffusion
Installation
Wall-mounted
Composition
NA1000MR controller and NA1000DII hydrogen transmitter
Display
TFT256 color LCD
Centralized fixed hydrogen monitoring for generator and hydrogen operating points
Controller supports multi-channel 4 to 20 mA transmitters
Alarm records, branch alarms, general alarm, and DCS-friendly outputs
Back to catalogue

Product Overview

Fixed hydrogen leak monitoring for continuous online safety coverage, multi-point monitoring, and alarm control support.

Product Advantages

  • Centralized fixed hydrogen monitoring for generator and hydrogen operating points
  • Controller supports multi-channel 4 to 20 mA transmitters
  • Alarm records, branch alarms, general alarm, and DCS-friendly outputs

Technical Specifications

17 parameters
Output
1 to 8 channels of 4 to 20 mA current output, up to 16 channels
Explosion-proof rating
Ex ia IIC T4 Ga
Model
NA1000MS
Type
Fixed multi-channel hydrogen leak monitoring and alarm system
Sampling method
Natural diffusion
Installation
Wall-mounted
Composition
NA1000MR controller and NA1000DII hydrogen transmitter
Display
TFT256 color LCD
Input
1 to 8 two-wire channels, 4 to 20 mA transmitters, up to 16 channels
Alarm
1 to 16 branch alarms and 1 general alarm
Alarm storage
8000 alarm records
Controller voltage
210 to 230 VAC, 50/60 Hz
Controller dimensions
440 mm x 330 mm x 130 mm
Controller weight
9.5 kg
Transmitter range
0 to 4 %, 0 to 100 %LEL
Transmitter accuracy
Plus or minus 2% F.S
Environment
-10 to 50 C, 0 to 98 %RH

Application and Selection Checklist

This product is listed for fixed multi-point safety monitoring. Before selection, provide the following project information so the configuration can be reviewed against the actual operating conditions.

  • Gas composition and operating conditions
  • Required range, capacity, flow, or response
  • Power supply, interfaces, and installation space
  • Site environment and destination country
  • Quantity, schedule, and operating workflow
  • Required standards, drawings, tests, and certificates

Standards, Documentation, and Project Fit

Product suitability is determined by the selected model, configuration, operating conditions, interfaces, and destination requirements. A matching product in the same group is not automatically interchangeable.

Standards, declarations, calibration records, inspection documents, drawings, manuals, commissioning, training, and test scope vary by product and contract. State every required item in the inquiry and confirm it in writing before purchase.

Typical application descriptions on this page are selection references, not claims about a named customer installation. Final project fit requires review of the actual site data.

Frequently Asked Questions

What is NA1000MS Fixed Hydrogen Leak Monitoring System used for?

NA1000MS Fixed Hydrogen Leak Monitoring System is intended for fixed multi-point safety monitoring. Fixed hydrogen leak monitoring for continuous online safety coverage, multi-point monitoring, and alarm control support.

Which product group does NA1000MS belong to?

NA1000MS is listed in the H2 Leakage monitoring product group within the Hydrogen range.

What should be confirmed before selecting NA1000MS?

Confirm the application, gas conditions, required performance, utilities, connection interfaces, site environment, quantity, destination, and required technical documents.

Are standards and certificates available for NA1000MS?

Applicable standards, declarations, calibration or inspection records, and certificate availability depend on the selected model and destination. Confirm required documents in writing during the inquiry.